Contact Us

Anshan solenoid valve Co., Ltd. (General Plant)

Address: Industrial Park, Xing Long Office, Xiuyan Town, Xiuyan Manchu Autonomous County, Anshan, Liaoning.

Zip code: 114300

Sales Department Tel: (0412) 7824018/7822962

Fax: (0412) 7825018

Nuclear power office telephone: (0412) 7867160

Fax: (0412) 7867160


2/2 two-way solenoid valve

Your current location: Home >> Products >> Nuclear grade solenoid valve

2/2 two-way solenoid valve

  • Category:Nuclear grade solenoid valve

  • Hit Count:
  • Release Date:2018/11/09
  • more
  • Online Inquiry
Detailed

brief introduction


This series of products is a direct two-position two-way solenoid valve, which has two-way function, that is, both ends of the solenoid valve can be used as the inlet of the medium, the medium can flow forward and backward, and the valve also has the function of automatic check. The design and identification of solenoid valves conform to RCC-E, IEEE323, IEEE344, IEEE382, EJ/T and GB3836 standards. They are suitable for connecting or blocking control pipeline media in nuclear power plants and nuclear chemical industry with nuclear safety level requirements or in explosion-proof environments.




main features


1. direct acting structure, zero pressure difference can be opened and closed normally, and the action reliability is high.


2. according to the requirements, it can be equipped with manual devices, and can be operated manually under special conditions such as power failure and maintenance.


3. for vacuum applications, the vacuum can reach 1.33X10-7MPa.


4. the pressure balance technology can be used to seal the positive and negative directions in two directions.


5. all rubber parts can be used under high radioactive and temperature sudden environmental conditions.


6. High insulation level and high protection level: The insulation level of coil is H level, and can meet the application of LOCA environment.


7. meet seismic applications.


8. it can be designed and manufactured to be flameproof, and can be used in explosive environment.






Main technical parameters


1. security level: 1E/K1, K2, K3


2. aseismic categories: 1A


3. explosion-proof grade: see the appendix of this sample, "explosion-proof electromagnetic head parameter list".


4. design pressure: 4.0MPa (max)


5. design temperature: 100 C (max)


6. ambient temperature: -20 ~ +80 C


7. working medium: water, gas, oil, etc.


8. supply voltage: AC/DC24V 48V 110V 220V 380V and so on.


9. rated power: see the appendix of explosion-proof electromagnetic head parameter list.


10. working system: long term


11. response time: less than 2S


12. protection level: IP65


13. electrical interface: Cable crimping, cable outer diameter: 8.5 ~ 10mm


14. installation direction: arbitrary, preferably vertical.


15. fouling medium: 14um filter.


16. body material: stainless steel.


防爆电磁阀

防爆电磁阀

Related Tags:

Recently Viewed:

Related Products:

Related News:

share